DVPCOPM-SL

‧For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
‧Supports CANopen protocol
‧Connectable to 110 slaves
‧Max. baudrate: 1M bps
‧Max. network length: 1,000m

For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
Supports CANopen protocol
Connectable to 110 slaves
Max. baudrate: 1M bps
Max. network length: 1,000m
Specifications
Transmission method: CAN
Connector: Removable, 5.08mm
Serial baudrate: 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
Message type: PDO, SDO, SYNC, Emergency, NMT
Power supply voltage: 24 VDC (-15 to 20%)
Power consumption: 1.7 W
Electrical isolation: 500 VDC

ادامه مطلب

IFD9502

‧Supports DeviceNet protocol
‧Connectable to all Delta’s industrial automation products
‧Isolation in DeviceNet channel (incl. power supply)
‧Passed full compatibility test

Supports DeviceNet protocol
Connectable to all Delta’s industrial automation products
Isolation in DeviceNet channel (incl. power supply)
Passed full compatibility test
Specifications
Transmission method: CAN
Electrical isolation: 500 VDC
Connector: Removable, 5.08mm
Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
Serial baudrate: 125, 250, 500k bps
Network voltage: 24 VDC (11 to 25 VDC)
Current: 28 mA (typical), 125 mA impulse current (24 VDC)

ادامه مطلب

RTU-DNET

‧Supports DeviceNet protocol
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧The RS-485 port is connectable to max. 8 Modbus slaves
‧Max. baudrate: 500k bps

Supports DeviceNet protocol
Connectable to 8 DVP-S series analog I/O modules
Connectable to 256 points of digital I/O modules
The RS-485 port is connectable to max. 8 Modbus slaves
Max. baudrate: 500k bps
Specifications
Transmission method: CAN
Connector: Removable, 5.08mm
Message type: Explicit, I/O polled
Serial baudrate: 125, 250, 500k bps
Network voltage: 24 VDC (11 to 25 VDC)

ادامه مطلب

DVPDT02-H2

‧Supports DeviceNet protocol
‧For DVP-EH2 series PLC only
‧Max. baudrate: 500k bps

Supports DeviceNet protocol
For DVP-EH2 series PLC only
Max. baudrate: 500k bps
Specifications
Transmission method: CAN
Connector: Removable, 5.08mm
Message type: Explicit, I/O polled
Serial baudrate: 125k, 250k, 500k bps
Network voltage: 24 VDC (11 to 25VDC)
Electrical isolation: 500 VDC

ادامه مطلب

DVPDT01-S

‧Supports DeviceNet protocol
‧For DVP-S series PLC only
‧Max. baudrate: 500k bps

Supports DeviceNet protocol
For DVP-S series PLC only
Max. baudrate: 500k bps
Specifications
Transmission method: CAN
Connector: Removable, 5.08mm
Message type: Explicit, I/O polled
Serial baudrate: 125k, 250k, 500k bps
Network voltage: 24 VDC (11 to 25 VDC)
Electrical isolation: 500 VDC

ادامه مطلب

DVPDNET-SL

‧For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
‧Supports DeviceNet protocol
‧Connectable to 64 slaves
‧Max. baudrate: 500k bps
‧Max. network length: 500m
‧RTU mapping

For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
Supports DeviceNet protocol
Connectable to 64 slaves
Max. baudrate: 500k bps
Max. network length: 500m
RTU mapping
Specifications
Transmission method: CAN
Connector: Removable, 5.08mm
Message type: Explicit, I/O polled, bit-strobed, COS/CC
Serial baudrate: 125k, 250k, 500k bps
Network voltage: 24 VDC (11 to 25 VDC), supplied by power cable on the network
Power consumption: 1.7 W
Electrical isolation: 500 VDC

ادامه مطلب

IFD9507

‧Isolation in RS-485 channel (incl. power supply)
‧Supports EtherNet/IP protocol
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available
‧3 e-mail alarms (DI)

Isolation in RS-485 channel (incl. power supply)
Supports EtherNet/IP protocol
Smart Monitor
Supports webpage setup & on-line monitoring
Serial Virtual COM available
3 e-mail alarms (DI)
Specifications
Network Interface
Transmission method: IEEE 802.3, IEEE 802.3u
Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
Baudrate: 10/100M bps, auto-detection
Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, Modbus over TCP/IP, EtherNet/IP
Power supply voltage: 24 VDC (-15 to 20%)
Power consumption: 3 W
Insulation voltage: 500 V
RS-485 Interface
Connector 1: RJ-11, 10-pin feed through terminal
Connector 2: Removable
Transmission method: RS-485
Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
Data type: Modbus ASCII/RTU, user-defined

ادامه مطلب

IFD9506

‧Isolation in RS-485 channel (incl. power supply)
‧Supports Modbus TCP protocol
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available
‧3 e-mail alarms (DI)

Isolation in RS-485 channel (incl. power supply)
Supports Modbus TCP protocol
Smart Monitor
Supports webpage setup & on-line monitoring
Serial Virtual COM available
3 e-mail alarms (DI)
Specifications
Network Interface
Transmission method: IEEE 802.3, IEEE 802.3u
Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
Baudrate: 10/100M bps, auto-detection
Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, Modbus TCP
Power supply voltage: 24 VDC (-15 to 20%)
Power consumption: 3 W
Insulation voltage: 500 V
RS-485 Interface
Connector 1: RJ-11, 10-pin feed through terminal
Connector 2: 3-pin, removable
Transmission method: RS-485
Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
Data type: Modbus ASCII/RTU, user-defined

ادامه مطلب

RTU-EN01

‧A Modbus TCP slave
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧The RS-485 port is connectable to max. 32 Modbus slaves
‧Smart PLC if-then function
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available

A Modbus TCP slave
Connectable to 8 DVP-S series analog I/O modules
Connectable to 256 points of digital I/O modules
The RS-485 port is connectable to max. 32 Modbus slaves
Smart PLC if-then function
Smart Monitor
Supports webpage setup & on-line monitoring
Serial Virtual COM available
Specifications
Network Interface
Transmission method: IEEE 802.3, IEEE 802.3u
Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
Baudrate: 10/100M bps, auto-detection
Network protocols: ICMP, IP, TCP, UDP, DHCP, NTP, Modbus TCP, HTTP
Power supply voltage: 24 VDC (-15 to 20%)
Power consumption: 2 W
Insulation voltage: 500 V
RS-485 Interface
Transmission method: RS-485
Connector: Removable
Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
Data type: Modbus ASCII/RTU

ادامه مطلب

DVPEN01-SL

‧For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
‧Supports Modbus TCP protocol
‧Max. baudrate: 100M bps
‧Modbus TCP connections
Client: 32
Server: 16
‧Smart data exchange
‧RTU mapping
‧Simple firewall
‧E-mail alarm

For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
Supports Modbus TCP protocol
Max. baudrate: 100M bps
Modbus TCP connections
Client: 32
Server: 16
Smart data exchange
RTU mapping
Simple firewall
E-mail alarm
Specifications
Transmission method: IEEE 802.3, IEEE 802.3u
Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
Baudrate: 10/100 Mbps, auto-detection
Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, NTP, Modbus TCP
Power supply voltage: 24 VDC (-15 to 20%)
Power consumption: 1.5 W
Insulation voltage: 500 V

ادامه مطلب